35+ years of excellence in business.

Over 50 years specializing in fluid dynamics.

credit-cards-accepted1

Flo Fab Pumps

Split Case Double Suction

Split Case Double Suction Pumps
Double suction split case type pumps are most commonly applied for heating and air conditioning systems or other industrial applications.

Series: 4800U 4800L 4800 4800 H/V
Type: Single Stage,
Double Suction Split Case
Single Stage,
Double Suction Split Case
Single Stage,
Double Suction Split Case
Horizontal or Vertical Single Stage Double Suction, Split Case

Capacities:

up to 12,000 USGPM
(2,725 m3/hr)
up to 12,000 USGPM
(2,725 m3/hr)
up to 7,500 USGPM
(1,703 m3/hr)
up to 12,700 USGPM
(2,884 m3/hr)
Head: up to 750 ft (227m) up to 750 ft (227m) up to 625 ft (190m) up to 560 ft (170m)
Pressure: up to 231 PSI (1,593 kPa) up to 231 PSI (1,593 kPa) up to 350 PSI (2,413 kPa) up to 365 PSI (2,517 kPa)
Horsepower: up to 800 HP (597 kw) up to 800 HP (597 kw) up to 600 HP (447 kw) up to 800 HP (597 kw)
Drives: Electric Motors, Diesel engines
Steam turbines
Electric Motors, Diesel engines
Steam turbines
Electric Motors, Diesel engines
Steam turbines
Electric Motors, Diesel engines
R.A.G.D.
Liquids Pumped: Water and clear liquids Water and clear liquids Water and clear liquids Water and clear liquids
Temperature: up to 220oF (105oC) up to 220oF (105oC) up to 225oF (107oC) up to 220oF (105oC)
Materials of Construction: Cast Iron, Bronze fitted as standard, other materials also available Cast Iron, Bronze fitted as standard, other materials also available Cast Iron, Bronze fitted Cast Iron, Bronze fitted as standard, other materials also available
image image image image

Vertical Single Stage

Vertical Single Stage Pumps
Vertical Single Stage type pumps are most commonly applied for heating and air conditioning systems or other industrial applications.

Series: 880 880RI
Type: Compact In-line Centrifugal Vertical In-line Centrifugal Power frame pump mounted with flexible coupling

Capacities:

up to 3,000 USGPM
(148 m3/hr)
up to 3,000 USGPM
(148 m3/hr)
Head: up to 650 ft (198m) up to 650 ft (198m)
Pressure: up to 250 PSI (1,724 kPa) up to 250 PSI (1,724 kPa)
Horsepower: up to 200 HP (149 kw) up to 200 HP (149 kw)
Drives: JM Electric Motors HP Electric Motors
Liquids Pumped: Water and clear liquids Water and clear liquids
Temperature: up to 300oF (149oC) up to 300oF (149oC)
Materials of Construction: Cast Iron, Bronze fitted as standard, other materials also available Cast Iron, Bronze fitted as standard, other materials also available
image image

Horizontal End Closed Coupled

Series: 1000
Type: End Suction, Close Coupled

Capacities:

up to 1,900 USGPM
(431 m3/hr)
Head: up to 280 ft (85m)
Pressure: up to 175 PSI (1,206 kPa)
Horsepower: up to 200 HP (149 kw)
Drives: JM Electric Motors
Liquids Pumped: Water and clear liquids
Temperature: up to 300oF (149oC)
Materials of Construction: Cast Iron, Bronze fitted as standard, other materials also available
image

Horizontal Base Mounted End Coupled

Series: 2000 2300/2600 "T"
Type: Horizontal, Base Mounted End
Suction, Back Pullout
Horizontal, Base Mounted End
Suction, Back Pullout
Self-Priming pump

Capacities:

up to 1,900 USGPM
(431 m3/hr)
up to 6,500 USGPM
(1,476 m3/hr)
up to 13,000 USGPM
(2,951 m3/hr)
Head: up to 280 ft (85m) up to 700 ft (213m) up to 210 ft (64m)
Pressure: up to 175 PSI (1,206 kPa)
with 125# flanges
up to 175 PSI (1,206 kPa)
with 125# flanges
up to 175 PSI (523 kPa)
Horsepower: up to 200 HP (149 kw) up to 500 HP (373 kw) up to 400 HP (298 kw)
Drives: T Frame Electric Motors
or Diesel engines
T Frame Electric Motors
or Diesel engines
Horizontal Electric Motors
or Diesel engines
Liquids Pumped: Water and waste liquids Water and waste liquids Sewage or clean water
Temperature: up to 300oF (149oC) up to 300oF (149oC) up to 220oF (105oC)
Materials of Construction: Cast Iron, Bronze fitted as standard
other materials also available
Cast Iron, Bronze fitted as standard
other materials also available
#304 Stainless Steel
image image

 

Column Sump and Sewage

"Sump Pump" is the term applied to units suitable for handling clear liquids or small solids such as may pass through the strainer with which each pump is equipped. Efficiencies in some ratings are higher than with pumps specifically designed for solids handling.

Series: SUP SEP
Type: Column Effluent Column Sewage

Capacities:

15 to 500 USGPM
(3.4 to 112.87 m3/hr)
50 to 1400 USGPM
(11.4 to 316 m3/hr)
Head: up to 88 ft (26.8m) up to 120 ft (36.6m)
Pressure:
Horsepower: up to 20 HP (15 kw) up to 40 HP (30 kw)
Drives: Vertical Electrical Motor Vertical Electrical Motor
Liquids Pumped: Water and waste liquids Water, sewage and waste liquids
Temperature:
Materials of Construction:
image image

Closed Coupled Centrifugal

Series: PSF PST
Type: Flanged Close Coupled Centrifugal NPT Close Coupled Centrifugal

Capacities:

13 to 380 USGPM 
(3 to 86 m3/hr)
up to 52 USGPM 
(12 m3/hr)
Head: 33 to 285 ft (10 to 87m) up to 38 ft (12m)
Pressure: up to 145 PSI (1,000 kPa) up to 115 PSI (793 kPa)
Horsepower: up to 200 HP (149 kw) up to 200 HP (149 kw)
Drives: Electric Close Coupled Motors Electric Close Coupled Motors
Liquids Pumped: Water and clear liquids Water and clear liquids
Temperature: up to 225oF (107oC) up to 225oF (107oC)
Materials of Construction: #304 Stainless Steel #304 Stainless Steel
     